Eye Doctor Arizona
Eye Surgery Arizona

  Zeiss IOLMaster®
Online Users Instruction Manual V.5
printable version
 
IOL Power Calculations IOL Power Calculations
Optical Biometry Optical Biometry
Lens Constants Lens Constants
Haag Streit LENSTAR® Haag Streit LENSTAR
Zeiss IOLMaster® Zeiss IOLMaster
IOLMaster VIDEO Tutorial
IOLMaster Manual V.5 IOLMaster User Manual V.5
General Operation
Data Management
Backup Data
Restore Data
Import Data
IOLMaster Manual V.4 IOLMaster User Manual V.4
IOL Master Manual Download IOLMaster Checklist (pdf)
IOL Master Manual Download IOLMaster Manual V.5.4 (pdf)
IOL Master Manual Download IOLMaster Manual V.5 (pdf)
SIA Calculator
Disclaimer
Physician Downloads SIA Calculator
Links
References
Special Thanks

Zeiss IOLMaster Customer Service: 1-877-486-7473 ext. 4030

IOLMaster — Backup Data / Save Data

Create a Backup Copy IOLMaster Backup

With the Backup function, you can save to a CD-RW the patient data used for the optimization of IOL constants together with the IOL data of all surgeons and corresponding lenses used for the IOL calculation.

IOLMaster Arizona NOTE: If you wish to export to a CD-RW, you must insert a formatted CD-RW into the drive. The CD-RW must be formatted elsewhere (e.g. office PC) in UDF format. Alternatively, use one of the formatted CD-RWs as supplied. For exporting to an USB flash drive, the latter should enable at least a transfer rate to USB-1.1.

IOL Master warning WARNING: A compressed and password-protected file is created in the CD-RW. Do not attempt to read or manipulate this file using other programs.

The respective measurement readings are saved together with the patient’s personal data, regardless of the set deletion date.

The backup process also includes the tables used for IOL constant optimization (assignment of surgeon/lens/patient/eye/post-operative data). Additionally, the IOL constants currently used for calculation will be saved for all surgeons.

IOLMaster Arizona NOTE: In this way, all critical patient and IOL data can be saved together with the data required for lens optimization. Individual values for axial length, corneal curvature / refractive power, anterior chamber depth, WTW are not saved and may get lost, e.g. in the case of a defect in the hard disk.

Follow this procedure to create a backup copy:

IOLMaster Backup
  • In the User Database activate Administrator.
  • Click the Backup command button to initiate the backup process.
  • Insert a UDF-formatted CD-RW into the drive.
  • Confirm with OK.
  • It may be necessary to delete existing data on the CD-RW (confirm with YES). Answering with NO will abort the backup process. The data will now be copied to the CD-RW A progress bar informs you of the status of the copying process.
  • Upon success of data backup, message will be received.

IOLMaster Help
TOP

Zeiss IOLMaster® Tutorial Version 5

Zeiss IOLMaster®

Optical Biometry

Intraocular Lens Power Calculations


East Valley Ophthalmology
5620 East Broadway Road
Mesa, Arizona 85206

Tel: +1-480-981-6111
FAX: +1-480-985-2426

Arizona's Top Eye Doctors - East Valley Ophthalmology provides this online information for educational and communication purposes only and it should not be construed as personal medical advice. Information published on this website is not intended to replace, supplant, or augment a consultation with an eye care professional regarding the viewer/user's own medical care. East Valley Ophthalmology's disclaims any and all liability for injury or other damages that could result from use of the information obtained from this site. Please read our full Terms, Privacy, Infringement

Eye Doctors for Mesa, Gilbert, Chandler, AZ and surrounding areas.

A few of our featured topics:


TOP

Copyright East Valley Ophthalmology. All rights reserved.