Haag Streit LENSTAR®.


Haag Streit Lenstar

Requirements


The EyeSuite software used to control and collect data from diagnostic devices of Haag-Streit, mainly the AT 900 D Applanation Tonometer, the IM 900 Imaging Module, the LS 900 LENSTAR optical biometer and the Octopus series perimeters. The software is supplied on a CD-ROM containing both the MySQL server software and the EyeSuite application(s).

Minimum PC Requirements

  • Intel® Core™ 2 Duo 2.0GHz
  • Operating Systems: Windows XP (Service Pack 3), Windows Vista (Service Pack 1), Windows 7
  • Memory: 2 GB (XP), 4 GB (Vista / Windows 7)
  • Hard disk: 160 GB hard disk
  • CD-ROM / DVD
  • USB2.0 interface (ICH5) for Biometry, Imaging and Tonometry
  • T100 (100MHz) Ethernet interface for Perimetry
  • Display minimum: 1280x800 optimal: 1280x1024

Data-storage Requirement for EyeSuite Biometry Examinations

The data-storage medium should conform to the expected use of the device. The volume of data handled can be calculated as follows:

Standard measurement 1.8 Mbyte
Measurement with basic screen image 2.7 Mbyte

Example (moderate volume facility):

An average of 5 patients are measured on 250 working days. In the course of this, both eyes are each measured 5 times.

Standard measurement 250 x 5 x 2 x 5 x 1.8 = 22.5 GB / year
Measurement with red free (green light) image 250 x 5 x 2 x 5 x 2.7 = 33.8 GB / year

Example (high volume facility):

An average of 20 patients are measured on 360 working days. In the course of this, both eyes are each measured 5 times.

Standard measurement 360 x 20 x 2 x 5 x 1.8 = 130 GB / year
Measurement with red free (green light) image 360 x 20 x 2 x 5 x 1.8 = 200 GB / year

LENSTAR Help
TOP

Haag Streit LENSTAR®

Optical Biometry

Intraocular Lens Power Calculations


East Valley Ophthalmology
5620 East Broadway Road
Mesa, Arizona 85206

Tel: +1-480-981-6111
FAX: +1-480-985-2426

Arizona's Top Eye Doctors - East Valley Ophthalmology provides this online information for educational and communication purposes only and it should not be construed as personal medical advice. Information published on this website is not intended to replace, supplant, or augment a consultation with an eye care professional regarding the viewer/user's own medical care. East Valley Ophthalmology's disclaims any and all liability for injury or other damages that could result from use of the information obtained from this site. Please read our full Terms, Privacy, Infringement

Eye Doctors for Mesa, Gilbert, Chandler, AZ and surrounding areas.

A few of our featured topics:


TOP

Copyright East Valley Ophthalmology. All rights reserved.