Eye Surgery Arizona

  IOLMaster Lens Constants
By Lens Manufacturer
Cataract Surgery Arizona
 
IOL Power Calculations IOL Power Calculations
Zeiss IOLMaster Zeiss IOLMaster
IOLMaster Tutorial V.5 Cataract Surgery Arizona
IOLMaster Tutorial V.4 IOLMaster User Manual V.4
IOLMaster Lens Constants
Specific Lens Constants
Haigis Formula
ULIB in Germany
IOL Master Manual Download IOLMaster Manual V.5 (pdf)
IOL Master Manual Download IOLMaster Manual V.4 (pdf)
IOL Master Manual Download IOLMaster Manual V.3 (pdf)
IOL Master Manual Download IOLMaster Checklist (pdf)
Disclaimer
Physician Downloads SIA Calculator
Links
References
Special Thanks

Zeiss IOLMaster Customer Service: 1-877-486-7473 ext. 4030

IOL Master Lens Constants.

Below is an alphabetical listing of some IOLs for which optimization for the IOLMaster has not yet been posted to the ULIB site. Other IOLs listed are based on data from multiple surgeons and show a good correlation. These lens constants are offered only as a recommendation for a starting point and not as something definitive. Each surgeon must individually optimize lens constants on their own. (This list will be expanded in the near future; please check back for more information.)

Click on the links to view
Specific IOLMaster lens constants
.

Alcon Lenses:

CZ70BD

Plus (+) MA60MA

Minus (-) MA60MA

MC60CM

MN60D3 Restor (3-piece) IOL

MTA-series
Anterior Chamber IOLs — (MTA2UO through MTA7UO)

 

MZ60MD

SN60D3 Restor (single piece) IOL

SN6AD1 & SN6AD3 Aspheric ReStor (single piece) IOL

SN6AT3, SN6AT4 and SN6AT5 Aspheric AcySofr Toric IOL

SN60WF aspheric IOL

AMO Lenses:

AC21D3 DuraLens II

ReZoom NXG1

 

ZA9003

ZCB00 Tecnis

Bausch & Lomb:

L122UV

LI61AO

 

S122UV

Eyeonics:

AT-45 Crystalens

 

AT-50 Crystalens

Staar:

AQ-2010V

AQ-5010V

 

CQ-2015

It is important to remember that these numbers simply represent a starting point, with optimization to follow.

In no way are these numbers meant to be definitive.

To begin the process of optimization, please visit our Physician Downloads .

For the more commonly used IOLs, we recommend visiting the User Group for Laser Interference Biometry website. This is maintained by Dr. Wolfgang Haigis at the University of Wuerzburg Eye Hospital in Wuerzburg Germany.

Cataract Surgery Arizona

IOLMaster Help
TOP

Zeiss IOL Master

Intraocular Lens Power Calculations


East Valley Ophthalmology, Arizona's premier eye specialists, provides this on-line information for educational and communication purposes only and it should not be construed as personal medical advice. Information published on this website is not intended to replace, supplant, or augment a consultation with an eye care professional regarding the viewer/user's own medical care. East Valley Ophthalmology's disclaims any and all liability for injury or other damages that could result from use of the information obtained from this site. Please read our full Disclaimer